{"id":18190,"date":"2022-11-08T10:01:13","date_gmt":"2022-11-08T10:01:13","guid":{"rendered":"https:\/\/rnrmachines.com\/?post_type=project&#038;p=18190"},"modified":"2023-06-05T05:44:33","modified_gmt":"2023-06-05T05:44:33","slug":"chilled-water-dryer","status":"publish","type":"project","link":"https:\/\/rnrmachines.com\/index.php\/product\/chilled-water-dryer\/","title":{"rendered":"Chilled Water Dryer"},"content":{"rendered":"<div class=\"wpb-content-wrapper\">[vc_row gap=&#8221;64&#8243; element_id=&#8221;544602&#8243; css=&#8221;.vc_custom_1548940421216{padding-bottom: 96px !important;}&#8221;][vc_column animation_delay=&#8221;0&#8243; element_id=&#8221;172162&#8243; crp=&#8221;480:i:i,480-768:i:i,768-1024:i:i,1024-1280:i:i,1280-1366:i:i,1366-1600:i:i,1600-1920:i:i&#8221; offset=&#8221;vc_col-lg-4 vc_col-md-5 vc_col-xs-12&#8243; el_class=&#8221;product-menu&#8221;][vc_wp_custommenu nav_menu=&#8221;68&#8243;]<span class=\"et-gap et-clearfix et-gap-579052 hide1024\"><\/span>[\/vc_column][vc_column animation_delay=&#8221;0&#8243; element_id=&#8221;21206&#8243; crp=&#8221;480:i:i,480-768:i:i,768-1024:i:i,1024-1280:i:i,1280-1366:i:i,1366-1600:i:i,1600-1920:i:i&#8221; offset=&#8221;vc_col-lg-8 vc_col-md-7 vc_col-xs-12&#8243;]<h1 class=\"et-heading text-align-left tablet-text-align-inherit mobile-text-align-inherit animate-false no-animation-type\" id=\"et-heading-398218\" data-delay=\"0\" data-mobile-font=\"inherit\" data-mobile-line-height=\"inherit\" data-tablet-landscape-font=\"inherit\" data-tablet-portrait-font=\"inherit\" data-tablet-landscape-line-height=\"inherit\" data-tablet-portrait-line-height=\"inherit\" data-parallax=\"false\" data-move=\"false\" data-coordinatex=\"0\" data-coordinatey=\"0\" data-speed=\"10\"><span class=\"text-wrapper\"><span class=\"text\">Chilled Water Dryer<\/span><\/span><\/h1><span class=\"et-gap et-clearfix et-gap-803736\"><\/span>[vc_column_text animation_delay=&#8221;0&#8243; el_class=&#8221;justify&#8221;]RNR\/ Exal manufactures some of the largest Chilled Water Air\/Gas Dryers globally for Compressed Air \/ Gas. The Chilled Water dryer is similar to a refrigerated dryer but uses chilled water for cooling Compressed Air\/ Gas instead of a refrigerant.<\/p>\n<p>Compressed Air\/Gas enters the dryer through a Gas to Gas heat exchanger. The incoming Gas\/ Air is pre-cooled using the outgoing dry Gas\/ Air. This economizer heat exchanger can enable a reduction in cooling heat-load 10- 40% or more depending on the working pressure and compressor discharge temperature etc.<\/p>\n<p>The pre-cooled Gas \/ Air then is cooled using a chilled water. In the process of cooling, the moisture in the Gas \/ Air condenses. The pressure dewpoint achieved is around 10<sup>o<\/sup>C. The limitation here is the chilled water temperature. A dewpoint of Chilled water temperature +2<sup>o<\/sup>C can be achieved. For dewpoints as low as 3<sup>o<\/sup>C, client can provide chilled glycol or equivalent mixtures which operate at lower temperatures (At pressure dewpoints less than 3<sup>o<\/sup>C moisture starts forming ice and can lead to heat exchanger failure even under high pressure.)<\/p>\n<p><b><u>NOTE<\/u><\/b>: The chilled water dryer is primarily used at plants where there are chillers with excess chilled water Tonnage of Refrigeration. Typically, branded flooded screw \/ centrifugal chillers (Carrier, Diakin, Trane etc.) have very low KW\/ TR (approximately 0.5 to 0.6 KW\/TR.) The chilled water dryer is a highly economical solution vs a refrigerated dryer (in both CAPEX + OPEX) in case the application can tolerate a higher pressure dewpoint. A point to be noted here is that the chilled water dryer is dependent on the chiller for performance. A refrigerated dryer is its own individual isolated system. In case of chilled water dryer an issue of chiller(s) will result in all dryers in connection not performing. There is also the possibility of compressed air entering a central chilled water line. This dryer must be made robust.[\/vc_column_text][vc_column_text animation_delay=&#8221;0&#8243; el_class=&#8221;justify&#8221;]RNR\/ Exal Chilled Water Dryers can be designed for blowers and compressors. This includes working pressure as low as 0.5 Bar(g) and up to 70 Bar(g).<\/p>\n<p>All our systems are designed based on proper heat load calculations coupled with simulation based evaluation of each heat exchanger to determine pressure drop and heat transfer area effectiveness. For the heat-load we take into account the Kg\/Hour of Compressed Gas\/ Air and Moisture entering the system. In addition, we consider the moisture quantity at the inlet of dryer based on compressor inter-stages, compressor suction etc. The cooling required to condense the moisture to the desired dewpoint is based on the Chilled Water to Air\/ Gas heat-load and the pre-cooler effectiveness.[\/vc_column_text]<span class=\"et-gap et-clearfix et-gap-361243\"><\/span><h5 class=\"et-heading text-align-left tablet-text-align-inherit mobile-text-align-inherit animate-false no-animation-type\" id=\"et-heading-449430\" data-delay=\"0\" data-mobile-font=\"inherit\" data-mobile-line-height=\"inherit\" data-tablet-landscape-font=\"inherit\" data-tablet-portrait-font=\"inherit\" data-tablet-landscape-line-height=\"inherit\" data-tablet-portrait-line-height=\"inherit\" data-parallax=\"false\" data-move=\"false\" data-coordinatex=\"0\" data-coordinatey=\"0\" data-speed=\"10\"><span class=\"text-wrapper\"><span class=\"text\">Our Chilled Water Dryers have the following features:<\/span><\/span><\/h5><span class=\"et-gap et-clearfix et-gap-382586\"><\/span><ul id=\"et-icon-list-400519\" class=\"justify et-icon-list small full\"><li><div class=\"icon-wrap\"><div class=\"icon small\"><span class=\"small fas fa-angle-double-right\"><\/span><\/div><\/div><div>Completely skid mounted and complete unit with insulation.<\/div><\/li><li><div class=\"icon-wrap\"><div class=\"icon small\"><span class=\"small fas fa-angle-double-right\"><\/span><\/div><\/div><div>Rugged Shell and Tube construction. Customized low pressure drop &lt; 0.1 Bar (optional )*<\/div><\/li><li><div class=\"icon-wrap\"><div class=\"icon small\"><span class=\"small fas fa-angle-double-right\"><\/span><\/div><\/div><div>Temperature indicators to indicate Dewpoint, Inlet Temperature etc.<\/div><\/li><\/ul><span class=\"et-gap et-clearfix et-gap-918762\"><\/span>[vc_column_text animation_delay=&#8221;0&#8243; el_class=&#8221;justify&#8221;]* RNR \/ Exal has the lowest committed and delivered pressure drops in the industry. Our systems have been designed for very low-pressure applications such as use with blowers where working pressure is 0.5 Bar(g) and pressure drop is critical.[\/vc_column_text]<span class=\"et-gap et-clearfix et-gap-968566\"><\/span><span class=\"et-gap et-clearfix et-gap-795915\"><\/span>[vc_row_inner][vc_column_inner][vc_images_carousel images=&#8221;18191&#8243; img_size=&#8221;full&#8221; autoplay=&#8221;yes&#8221; wrap=&#8221;yes&#8221;][\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column][\/vc_column][\/vc_row]\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row gap=&#8221;64&#8243; element_id=&#8221;544602&#8243; css=&#8221;.vc_custom_1548940421216{padding-bottom: 96px !important;}&#8221;][vc_column animation_delay=&#8221;0&#8243; element_id=&#8221;172162&#8243; crp=&#8221;480:i:i,480-768:i:i,768-1024:i:i,1024-1280:i:i,1280-1366:i:i,1366-1600:i:i,1600-1920:i:i&#8221; offset=&#8221;vc_col-lg-4 vc_col-md-5 vc_col-xs-12&#8243; el_class=&#8221;product-menu&#8221;][vc_wp_custommenu nav_menu=&#8221;68&#8243;][\/vc_column][vc_column animation_delay=&#8221;0&#8243; element_id=&#8221;21206&#8243; crp=&#8221;480:i:i,480-768:i:i,768-1024:i:i,1024-1280:i:i,1280-1366:i:i,1366-1600:i:i,1600-1920:i:i&#8221; offset=&#8221;vc_col-lg-8 vc_col-md-7 vc_col-xs-12&#8243;][vc_column_text animation_delay=&#8221;0&#8243; el_class=&#8221;justify&#8221;]RNR\/ Exal manufactures some of the largest Chilled Water Air\/Gas Dryers globally for Compressed Air \/ Gas. The Chilled Water dryer is similar to a refrigerated dryer but uses chilled water for cooling Compressed [&hellip;]<\/p>\n","protected":false},"featured_media":19131,"template":"","project-category":[],"project-tag":[],"class_list":["post-18190","project","type-project","status-publish","has-post-thumbnail","hentry"],"project_category_array":[],"project_image":[["full","https:\/\/rnrmachines.com\/wp-content\/uploads\/2022\/11\/Chilled-water_home.jpg"]],"_links":{"self":[{"href":"https:\/\/rnrmachines.com\/index.php\/wp-json\/wp\/v2\/project\/18190","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rnrmachines.com\/index.php\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/rnrmachines.com\/index.php\/wp-json\/wp\/v2\/types\/project"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rnrmachines.com\/index.php\/wp-json\/wp\/v2\/media\/19131"}],"wp:attachment":[{"href":"https:\/\/rnrmachines.com\/index.php\/wp-json\/wp\/v2\/media?parent=18190"}],"wp:term":[{"taxonomy":"project-category","embeddable":true,"href":"https:\/\/rnrmachines.com\/index.php\/wp-json\/wp\/v2\/project-category?post=18190"},{"taxonomy":"project-tag","embeddable":true,"href":"https:\/\/rnrmachines.com\/index.php\/wp-json\/wp\/v2\/project-tag?post=18190"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}